TESTS FOR EARLY FIRE HAZARD PROPERTIES
Your product identification of 15th November 1977
Our reference : E4053
 

The following results were obtained when the specimins described were subjected to the Test for early fire Hazard Properties of Materials of Australian Standard 1530 Part 3-1976:

Specimens  
Ignitability
Index
 
Spread
of flame
index
 

 

Heat
Evolved
Index
 
Smoke
Developed
Index
   
(0-20)
 
(0-10)
 
(0-10)
 
(0-10)
Terraton  
 

 

           
Mineral fibre ceiling tile consisting of:
Rockwool
Tapioca starch binder
Kaolin clay perlite filler
 

 

0
 

 

0
 

 

0
 

 

2
Tile thickness
:15mm
(nominal)
 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tile density
:360kg m­³
(nominal)
 

 

 

 

 

 

 

 

 

 

 

 

 

 

For the test each specimen was clamped to the specimen holder in three places

If this product is to be marketed in the form in which we have tested it , we ask that you forward a photocopy of this report for department records, to

Technical Information Branch,
Department of Construction,
Box 2807 AA, G.P.O,
MELBOURNE, VIC. 3001

LIGHT REFLECTANCE

 

..................3.2.3 Results

Patterns ST/721
1.00 0.86
2.00 0.81
3.00 0.79
4.00 0.86
5.00 0.86
6.00 0.83
7.00 0.84
8.00 0.83
9.00 0.81
10.00 0.84
11.00 0.83
12.00 0.84
13.00 0.86
14.00 0.80
15.00 0.78
Mean 0.83
Std. Deviation 0.03

 

 

                 
.......
..............
.